Service Manual JET3
112
Rev. 1.0
9.
Turn on the Ink flow sensor by pushing the button
<Ink flow sensor>
(1) again. Now
open the nozzle seal complete by using the
<arrow key>
(2). Now the Ink stream
must be in the middle of the charging tunnel and parallel to the deflecting plates.
Maybe you need to adjust the drop production unit again to get the exact position of
the Ink stream.
1
– Button <Ink Flow Sensor>
2
– Button <arrow>
10.
Close the nozzle seal and fix the inside cover.
(
Caution
: Watch out for damaging any tubes or cables!)
11.
Open the nozzle seal again and control the Ink stream position to finish the
adjustment.
1
2