36
Service Manual JET3
1021
1021=Extern Text: Double
print happened
External text: double print has occurred.
There were no new data sent.
Check the data handling of the
communication computer.
Check data cable and
connections.
1200
1200=Memory error in
SRAM
SRAM memory on the Cyclone Board
seems defective.
Change the controller board.
See the service document
"Exchange the Controller board
JET3up"
1201
1201=Check sum error.
Please check battery
voltage.
Checksum error when testing the battery
buffered SRAM memory.
Cause
1. After initial operation or after battery
replacement when mains has been
unplugged.
2. Battery is empty
3. Memory content is incorrect
Exchange the battery on the
controller board!
1202
1202=Memory access error
in SRAM
Software error!
Carry out a software update.
If software update is without
success, please contact
LEIBINGER
1203
1203=Low battery voltage.
Please remove battery
Battery voltage is under the limit.
So as not lose memory contents you should
exchange the battery when mains plugged,
but switched off (note! only trained staff)
Exchange the battery onto the
controller board!
Summary of Contents for JET3 up
Page 1: ...SERVICE MANUAL ...
Page 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Page 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Page 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Page 142: ...Service Manual JET3 142 Rev 1 0 ...
Page 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...