Service Manual JET3
Rev. 1.0
153
11. Unfix the frame with the valves from the top-hat rail and put an underlay above the ink
sensor to prevent soilings by ink.
Exchange the value:
Now you can easily pull the holdfast with
the valves out of the printer casing and
you can change either value for value
(if you want to change all values) or only
one definite value.
In this manual it is described how to
change the value AV.
The procedures for the other values are
exactly the same.
12.
Unscrew the screwcap of the tube and
push it back as far as possible.
13.
Strip the tube with an abductor.
(It is absolutely necessary to strip always all tubes which are connected with the
respective valve).
Fixed with cable tie
Unfixed without cable tie