Service Manual JET3
Rev. 1.0
155
17. Put the new AV Valve in the frame again and tighten the screw connection with a jaw
spanner (SW 10mm).
Caution:
To guarantee density of the hydraulic system it is absolutely necessary
to cut off the last piece of the tube which was damaged by strip the tube.
In case that the tube is too short you must change the hole tube!!!
18. Pull over the Tube on the connector.
19. Tighten the screwcap again.
20. Carry out a visual leak test, afterwards fix main pump, suction pump and the frame with
the valves on the top-hat rail, again.
To simplify the pull over
on the connector use a
wispy sandpaper.
Summary of Contents for JET3 up
Page 1: ...SERVICE MANUAL ...
Page 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Page 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Page 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Page 142: ...Service Manual JET3 142 Rev 1 0 ...
Page 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...