39
1224
1224=Stop count value
reached.
Print has stopped.
End of counter reached. Printing has been
stopped.
1300
1300=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball has not reached the upper sensor in
the viscometer
= Sensor broken, ball hangs down, any air in
the viscometer.
Start constant bleed function for
about 10 minutes to get the air
out of the system.
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
1301
1301=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball does not fall (top stuck)
Dirt in the Glassss tube.
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
1302
1302=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The ball has not left the upper sensor
Dirt in the Glassss tube
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.