Ventilation in the hydraulic cabinet
HV-cutoff at creepage current
Plastic containers are arranged in the
field of metal surfaces (PE-potential)
HV- and ink cutoff as well as nozzle sealing
at HV-flashovers
2.9 Safety measures at the place of installation
Mains connection!
The device has no mains switch and must only be connected to a
easy accessible plug socket in the direct vicinity of the place of
setting up!
Attention
– Danger of explosion!
The device should be only operated outside of explosive areas! The
installation has to be carried out according to the installation
instructions of the manufacturer!
Attention
– Danger of explosion!
The device has to be integrated in the lightning protection concept
of the operator!
Attention
– Danger of explosion!
Precautions regarding electrostatics have to be carried out!
Installation of the device
The device must be installed in a well ventilated room only and must
be kept away from any source of heat, flame or sparks, e.g. radiant
heater, etc.
A place of setting up must be selected with sufficient load bearing
capacity and stability. When setting up it must be observed that sufficient
movement space is available for the operating and service personnel.
Solvents are processed in the device, sufficient room ventilation must be
ensured!
2.10 Prior to assembly the place of setting up must be cleaned
of dirt and contamination (residue of lubricants etc.). The
working place surroundings should be kept clean at all
times in order to ensure unrestricted access to the
JET3up device.
Summary of Contents for JET3 up
Page 1: ...SERVICE MANUAL ...
Page 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Page 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Page 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Page 142: ...Service Manual JET3 142 Rev 1 0 ...
Page 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...