33
111
111=Internal communication
error
Internal communication problem.
A CPU has sent a message, but get no
response from the recipient or the message.
Typical error when a CPU crashes, hangs,
or has been reset. If there no principled
software error and this error occurs more
often might this an indication of a hardware
failure. Cyclone Board defective (unlikely),
5V power supply is unstable or very brief
network drop outs (more likely). Currently
the printer GUI is resetting the system if
such an error appears, to try to get the
system working again.
112
112=Internal communication
error
Internal communication problem.
A CPU has sent a message, but get no
response from the recipient or the message.
Typical error when a CPU crashes, hangs,
or has been reset. If there no principled
software error and this error occurs more
often might this an indication of a hardware
failure. Cyclone Board defective (unlikely),
5V power supply is unstable or very brief
network drop outs (more likely). Currently
the printer GUI is resetting the system if
such an error appears, to try to get the
system working again.
113
113=Internal communication
error
Internal communication problem:
A CPU (RIP) has sent a message (identifier)
to a different CPU which is unknown.
Reboot again the system.
Carry out a software update.
Change the controller-board.
See the service document
"Exchange the Controller board
JET3up"
If no success, please contact
LEIBINGER
Summary of Contents for JET3 up
Page 1: ...SERVICE MANUAL ...
Page 12: ...Service Manual JET3 12 Rev 1 0 2 4 Safety sticker Figure 1 ...
Page 58: ...Service Manual JET3 58 Rev 1 0 7 2 Documentations for SK4 Torsional moments for SK4 ...
Page 99: ...Service Manual JET3 Rev 1 0 99 7 3 Documentations for SK6 Torsional moments for SK6 ...
Page 142: ...Service Manual JET3 142 Rev 1 0 ...
Page 144: ...Service Manual JET3 144 Rev 1 0 7 4 Hydraulic 1 Hydraulic scematic ...