Service Manual JET3
Rev. 1.0
127
9. Rotate the motor spindle
clockwise
with a slotted head screwdriver to screw out the
gutter tube.
ATTENTION: The thread should not be damaged!
10. Put in the new gutter tube and rotate the motor spindle
counter clockwise
to screw in
the gutter tube.
ATTENTION: The thread should not be damaged!
Then put on the retaining plate again
Attention:
You must take care that you put in the plate by the correct side.
The two step drills must be inside.
Step drills