![LeCroy WaveRunner 104MXI Operator'S Manual Download Page 70](http://html1.mh-extra.com/html/lecroy/waverunner-104mxi/waverunner-104mxi_operators-manual_1866369070.webp)
W
AVE
R
UNNER
X
I
S
ERIES
70
WRXi-OM-E Rev B
I
NTERVAL
T
RIGGER
S
ETUP
1. Touch
the
Trigger
descriptor label.
2. If applicable, touch the
Smart
trigger button, then the
Interval
trigger button.
3. Touch
inside
the
Trigger Source
field and select a source on which to trigger.
4. If available, touch inside the
Coupling
field and select a coupling mode.
5. Touch
inside
the
Level
field and enter a value using the pop-up numeric keypad.
6. Select positive or negative polarity.
7. Touch
the
LessThan
button and enter a pulse-width value in the
Upper Limit
field.
o
Or touch the Greater Than button and enter a value in the Lower Limit data entryfield.
o
Or touch the In Range button.
8. Touch the Delta button to set up a nominal range, plus or minus a delta value in seconds. Touch inside the
7. Nominal Width and Delta data entry fields and enter values using the pop-up numeric keypads.
Touch the Limits button to set up a precise range. Touch inside the Lower Limit and Upper Limit data entry
fields and enter values using the pop-up numeric keypads.
o
Or, if available, touch the Out Of Range button and perform the same Delta or Limits setup as for In
Range triggering.
Dropout Trigger
Used primarily in single-shot applications, and usually with a pre-trigger delay, Dropout trigger can detect lost
signals. The trigger is generated at the end of the timeout period following the last trigger source transition.
H
OW
D
ROPOUT
T
RIGGER
W
ORKS
Dropout Trigger: occurs when the timeout has expired. The bold upward-pointing arrows show where the trigger occurs.
D
ROPOUT
T
RIGGER
S
ETUP
1. Touch
the
Trigger
descriptor label.
2. If applicable, touch the
Smart
trigger button, then the
Dropout
trigger button.
3. Select
Positive
or
Negative
polarity.
4. Touch
inside
the
Trigger after
timeout data entry field and enter a time value, using
the pop-up keypad.
5. Enter a voltage level in the
Level
field.