Trigger Counter
Checking the
Reset trigger counter before starting a new acquisition
checkbox clears the trigger counter
each time the oscilloscope issues an arm acquisition command. This applies when you have set a trigger Holdoff
condition in the
Trigger
dialog in either time or events:
The default condition of this control is off (unchecked).
Performance Optimization
You can set up the oscilloscope to optimize either calculating speed or display speed. If the display update rate is
of primary concern to you, optimize for Display. If acquisition and analysis are more important, optimize for
analysis. Optimizing for analysis can be useful when persistence or averaging is used, giving higher priority to
waveform acquisition at the expense of display update rate.
The choices are presented as a spectrum with highest values at the extremes:
In the menu bar touch
Utilities
; then touch
Preferences
in the drop-down menu.
Touch one of the optimization icons.
Before you can send e-mail from the oscilloscope, it must first be configured.
1. In the menu bar touch
Utilities
, then
Preference Setup...
in the drop-down menu.
2. Touch
the
tab.
3. Choose an e-mail server protocol:
MAPI
(Messaging Application Programming Interface) is the Microsoft
interface specification that allows different messaging and workgroup applications (including e-mail, voice
mail, and fax) to work through a single client, such as the Exchange client included with Windows 95 and
Windows NT. MAPI uses the default Windows e-mail application (usually Outlook Express).
SMTP
(Simple
Mail Transfer Protocol) is a TCP/IP protocol for sending messages from one computer to another through a
network. This protocol is used on the Internet to route e-mail. In many cases no account is needed.
4. If you chose MAPI, touch inside the
Originator Address (From:)
field and use the pop-up keyboard to type in
the instrument's e-mail address. Then touch inside the
Default Recipient Address (To:)
field and use the
pop-up keyboard to enter the recipient's e-mail address.
5. If you chose SMTP, touch inside the
SMTP Server
field and use the pop-up keyboard to enter the name of
your server. Touch inside the
Originator Address (From:)
field and use the pop-up keyboard to type in the
instrument's e-mail address. Then touch inside the
Default Recipient Address (To:)
field and use the pop-up
keyboard to enter the recipient's e-mail address.
6. You can send a test e-mail text message by touching the
Send Test Mail
button. The test message reads
"Test mail from [name of oscilloscope's email address]."