Page 53 of 60
7
WARNING
SIGNAL
7.1 00: Emergency stop button not reset or cabinet door is not perfectly closed.
7.2 01: Spindle motor has been overloaded and tripped the thermal overload protector in magnetic starter.
Needs to be reset.
7.3 02: Spindle height is too high and has tripped the limit switch at end of travel.
7.4 03: Spindle height is too low and has tripped the limit switch at end of travel.
7.5 04: Spindle lifting motor (up & down) has been overloaded and tripped thermal overload protector in
magnetic starter. Needs to be reset.
7.6 05: Pneumatic cylinder (sensor 1) is not in the correct position.
-Make sure the notch on the tool holder is engaged with the tang on the shaft.
7.7 06: Draw bar (sensor 2) is not in the correct position.
-Make sure the notch on the tool holder is engaged with the tang on the shaft.
3-29