SH
PRoBlEM
CaUSE
SolUtion
21.
• Presence of grounds in
coffee cup.
• Coffee ground too fine.
• Worn grinders in grinder-
dispenser unit.
• Pump pressure above 9 bar.
• Sprinkler filter on unit clogged.
• Filter holes widened (filter
cup).
• Coarser grinding.
• Replace the grinders.
• Decrease the pump pressure.
• Check and clean with blind filter or
replace.
• Check and replace filter.
22.
• Coffee with too little
cream in cup (spurts out
of spout).
• Sprinkler filter on unit clogged. • Check and clean with blind filter or
replace.
23
• The cream in the cup is
too thin (it disappears
after a few seconds).
• Coffee extraction takes a long
time due to clogged filter.
• Coffee extraction too fast due
to clogged sprinkler filter.
• Water temperature too high.
• Clean or replace the filter.
• Clean or replace the sprinkler filter.
• Lower the temperature in the boiler.
• Adjust valve (flow variator) of serving
group.
24.
• Presence of depressions
in the coffee grounds
(looking inside the filter
cup).
• Sprinkler filter partly clogged.
• Clean or replace the sprinkler filter.
Note:
If it is not possible to solve the problem as described above, or if other malfunctions develop, contact the
authorized La San Marco service centre.
Summary of Contents for NEW 105 3
Page 2: ...italiano USO E MANUTENZIONE SERIE NEW 105 E Istruzioni Originali ...
Page 24: ...23 English USE AND MAINTENANCE SERIES NEW 105 E Translation of the original instructions ...
Page 68: ...67 deutsch BEDIENUNG UND WARTUNG SERIE NEW 105 E Übersetzung der Original Anweisungen ...
Page 91: ...deutsch ...
Page 92: ...91 español USO Y MANTENIMIENTO SERIE NEW 105 E Traducción de las instrucciones originales ...
Page 114: ...113 Portugûes MANUAL DE USO E MANUTENÇÃO SÉRIE NEW 105 E Tradução das instruções originais ...
Page 136: ...135 E HNIKA ΡΗΣΗ ΚΑΙ ΣΥΝΤΗΡΗΣΗ ΣΕΙΡΑ NEW 105 E Μετάφραση των αρχικών οδηγιών ...
Page 159: ...158 E HNIKA ...