442700/A
247
• Ethernet switch
Make sure that your selected Ethernet switch has a large bandwidth capacity. Minimum 1
Gb (1000BASE-T) is required.
• Ethernet cables
It is very important that high-quality Ethernet cables are used. You must use CAT-5E
STP (Shielded Twisted Pair) quality or better.
Neither tools nor instruments are required.
Context
When supplied, the Operating Panel is set up with the following communication parameters:
• IP Address: 157.237.60.20
• Subnet mask: 255.255.255.0
• Gateway: 157.237.60.1
The IP and MAC addresses for your Processor Unit are contained in a text file named
IPandMACaddress.txt
. The file contains the product name, IP address and MAC address in
the following format (example):
CS90
157.237.60.14
AC:1F:6B:1D:42:E6
Tip
To change which sonar to control, press
Sonar Select
on the Operating Panel. If you use your
Operating Panel to control more than two sonars, press
Sonar Select
repeatedly to select.
Procedure
1
Make the following preparations.
a
Insert the Ethernet switch between the Operating Panel and the Processor Unit.
Make sure that you use the correct Ethernet socket on the rear side of the
computer: ETH1
b
Connect each Processor Unit to the same Ethernet switch.