90
442700/A
Transmitting with fixed-time intervals
You can set up the CS90 system to transmit pings with a fixed time interval.
Context
Use
Transmission Mode
to control how often the CS90
system shall transmit its energy into the water. For normal
use, choose
Maximum
. If you choose
Maximum
, the CS90
system will transmit (ping) continuously and as often as
possible.
If you choose
Interval
, you must define the time between
each ping with the
Ping Interval
function.
Ping Interval
permits you to choose the time (in milliseconds) between
each transmission (ping).
Procedure
1
Open the
Operation
menu.
2
Set
Operation
to
Normal
.
3
Set
Transmission Mode
to
Interval
.
4
Specify the interval between each ping.
a
Select either side of the button to choose a value.
b
Select the middle of the button to open it.
If you have a keyboard connected to the CS90 system, type the requested value.
You can also change the value by selecting - and holding - the middle of the
button, and move the cursor sideways. Drag the cursor sideways to increase or
decrease the value. Release the mouse button when requested value is shown.
Related topics
Operating procedures, page 79
Choosing operating mode and key transmit parameters, page 84
Setting up the CS90 system for maximum echo refresh rate, page 88
Transmitting single pings, page 89
Transmitting with fixed-time intervals, page 90
Transmission Mode function, page 428
Simrad CS90 Reference Manual
Summary of Contents for Simrad CS90
Page 1: ...kongsberg com simrad Simrad CS90 REFERENCE MANUAL ...
Page 2: ......
Page 627: ...442700 A 625 Related topics Concept descriptions page 622 Concept descriptions ...
Page 683: ......
Page 684: ... 2021 Kongsberg Maritime ISBN 978 82 8066 213 2 ...
Page 685: ......
Page 686: ...Reference Manual Simrad CS90 ...