442700/A
189
3
Locate the
Hoist/Lower Switch
(S302).
4
Lowering the transducer:
a
Set the switch to position
LOWER
.
Lowering is automatically stopped when the
Lower Limit Switch
is activated. If
necessary, the transducer can be stopped in any position by setting the
Hoist/Lower
Switch
to
STOP
.
b
Set the switch to position
STOP
.
5
Hoisting the transducer:
a
Set the switch to position
HOIST
.
Hoisting is automatically stopped when the
Upper Limit Switch
is activated. If
necessary, the transducer can be stopped in any position by setting the
Hoist/Lower
Switch
to
STOP
.
b
Set the switch to position
STOP
.
6
Locate the
Hoist/Lower Switch
(S302). Set the switch to position
REMOTE
.
Note
For normal operation from the Operating Panel, the switch must be set to REMOTE.
7
Close the cabinet door.