INSTRUMENTS AND CONTROLS
FUNCTIONING
3-10
Turning engine off in normal conditions
q
When the ignition switch is turned to ON, the end screen JJ is displayed for 5 seconds, after which the monitor
switches off.
Faults detected during engine start
q
If faults are detected during engine start, the preliminary checks screen DD is immediately followed by the
'maintenance required' screen CC and the error screen EE.
q
After the preliminary checks screen DD is displayed for 2 seconds, the 'maintenance required' screen CC is
displayed.
q
After the 'maintenance required' screen CC is displayed for 30 seconds, the monitor returns to the standard
screen AA.
q
After the preliminary checks screen DD is displayed for 2 seconds, the error screen EE is displayed.
WEAM014802