Check fuel level and top up
WARNING
q
When refuelling, avoid spilling fuel, since this may cause a fire hazard. If fuel is spilled, wipe it up
immediately.
q
Fuel is highly flammable; do not use naked flames and do not smoke when refuelling. Hold the fuel
gun constantly in contact with the filler.
NOTICE
q
It is advisable to refuel after work, in order to avoid the formation of water condensate.
q
Avoid filling the tank completely and leave enough space for the fuel to expand.
q
After refuelling, tighten the cap thoroughly and lock it.
1.
Turn the ignition key to ON and check the fuel level from
the fuel gauge (1) on the machine monitor. After checking,
turn the ignition key OFF.
2.
If the level is low, open the closing panel, unscrew the fuel
tank plug (F) and top up with fuel.
q
Fuel tank capacity: 150 l