Machine model
PC12R-8
Classifi-
cation
Check item
Test Condition
Unit
Standard
value
Permissible
value
Blade
(measure the downward
movement of the edge
of the blade)
.
Engine stopped
.
Hydraulic oil temperature: 45 ± 55ëC
.
Raise the blade to its maximum height and
measure the height of the edge from the
ground.
Measure the downward after 15 mins.
mm
Max. 20
Max. 30
Boom
.
Engine speed: high idling
.
Hydraulic oil temperature: 45 ± 55ëC
.
Check leakages: on the cylinder on the si-
de opposite to the one under pressure.
H
Check one cylinder at a time
cm
3
/
min
2
Max. 5
Arm
2
Max. 5
Bucket
2
Max. 5
.
FOR THE MACHINE
20-14
PC12R-8 PC15R-8
Hydraulic
drift
of
working
equipment
Internal
cylinder
leakage
RKP01870
Summary of Contents for PC12R-8 MISTRAL
Page 1: ......
Page 2: ...40 28 PC15R 8 ...
Page 4: ...00 2 PC12R 8 PC15R 8 ...
Page 17: ...GROUP 10 ...
Page 18: ...40 28 PC15R 8 ...
Page 30: ...10 12 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 32: ...10 14 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...10 16 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...10 18 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 38: ...10 20 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 40: ...10 22 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...10 24 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 44: ...10 26 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ...10 61 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...10 112 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 132: ......
Page 133: ...GROUP 20 ...
Page 134: ...40 28 PC15R 8 ...
Page 158: ...20 24 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 198: ......
Page 199: ...GROUP 30 ...
Page 200: ...40 28 PC15R 8 ...
Page 283: ...GROUP 40 ...
Page 284: ...40 28 PC15R 8 ...
Page 317: ...40 33 PC12R 8 PC15R 8 PAGE INTENTIONALLY LEFT BLANK ...
Page 324: ......