286
Kollmorgen - June 2014
MMC Smart Drive Hardware Manual
-
S200-DLS DRIVE
9.1.4
Node Address Rotary Switches
Two rotary switches are used to set the drive address. Rotate the switch to the desired
address.
Addresses can be set to any number from 1 through 64. The top switch represents
values of base ten. The bottom switch represents values of base 1.
As an example, rotating the top switch (S3) to a setting of 2 equals the value of 20 (2 x
10). Rotating the bottom switch (S4) to a setting of 5 equals the value of 5. The actual
address setting is 25 (20 + 5).
Figure 9-2: Node Address Switches
S4 (10s)
S3 (1s)
0
5
1
4
3
2
6
7
8
9
0
5
1
4
3
2
6
7
8
9
Summary of Contents for MMC Smart Drive Series
Page 2: ......
Page 10: ...8 Kollmorgen June 2014 MMC Smart Drive Hardware Manual TABLE OF CONTENTS...
Page 14: ...12 Kollmorgen June 2014 MMC Smart Drive Hardware Manual INTRODUCTION TO THE MMC SMART DRIVE...
Page 164: ...162 Kollmorgen June 2014 MMC Smart Drive Hardware Manual 460V 3 PHASE MMC SMART DRIVE NEXTGEN...
Page 286: ...284 Kollmorgen June 2014 MMC Smart Drive Hardware Manual S200 DLS DRIVE Figure 9 1...
Page 316: ...314 Kollmorgen June 2014 MMC Smart Drive Hardware Manual MOTOR CABLES CONNECTORS...
Page 368: ...366 Kollmorgen June 2014 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Page 369: ...Kollmorgen June 2014 367 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Page 370: ...368 Kollmorgen June 2014 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Page 371: ...Kollmorgen June 2014 369 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Page 372: ...370 Kollmorgen June 2014 MMC Smart Drive Hardware Manual DECLARATIONS OF CONFORMITY...
Page 384: ...MMC Smart Drive Hardware Manual INDEX 382 Kollmorgen June 2014...
Page 386: ...384 Kollmorgen June 2014 MMC Smart Drive Hardware Manual SALES AND SERVICE...