Chapter 4 Setup after installation
MDC-7000/7900 Series
4-32
0092669002-07
Restore setup data from the internal memory:
(1) Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP LOAD] => [GO] and press ENT key.
4.5.2 External save of setup and map data (Cannot be performed while
transmitting)
To save setup and map data externally, this information can be later used to restore after a possible
malfunction.
The external memory uses an SD memory card.
CAUTION: Please do not use the SD memory card which is loaded with software program files.
Save setup and map data to SD card:
(1)
Insert SD memory card in the upper card reader on the rear of the Display unit.
(2) Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SD CARD] => select [SETUP SAVE], [MARK SAVE],
[TGT TRACK SAVE] or [OWN TRACK SAVE] => [GO], and press ENT key.
When SD memory card not inserted, [SD CARD] menu is shaded menu and cannot be operated.
Restore setup and map data from SD card:
(1) Insert SD card that was used to store settings in above procedure in the upper card reader on the
rear of the Display unit.
(2) Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SD CARD] => select [SETUP LOAD], [MARK LOAD],
[TGT TRACK LOAD] or [OWN TRACK LOAD] => [GO], and press ENT key.
When SD memory card not inserted or no data found on the card, [SD CARD] menu is shaded
menu and cannot be operated.
4.5.3 Parameter reset
Use this function as means to return the radar to its default settings as it was at first power on.
(1)
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [PARAMETER RESET] => [GO], and press ENT key.
4.5.4 MAP, Target Track and Past Position reset
Use this function as means to delete all the map, target track and past position data from radar internal
memory.
(1)
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [MAP/PAST RESET] => [GO], and press ENT key.
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......