Chapter 5 Troubleshooting and on board repair
MDC-7000/7900 Series
5-16
0092669002-07
5.3.2.8 Data such as heading, speed, latitude/longitude cannot be received
Is the NMEA input data
correct?
MENU> MAINTENANCE>
BITE> SERIAL MONITOR
Yes
Is the input signal level
right?
Can you see the NMEA
input data mark
“
●
”?
MENU> MAINTENANCE>
I/O > INPUT
No
Input sentence is
invalid.
Is MENU>
MAINTENANCE> I/O >
HDG, STW, COG/SOG,
POSITION set to
proper?
No
Set HDG, STW,
COG/SOG, position to
proper.
Is the cable connection
right?
Input/Output, Polarity
Confirm connection
cable.
Is the baud rate right?
Yes
No
No
Correct BAUDRATE.
MENU>
MAINTENANCE> I/O>
BAUDRATE
No
Take measures
required to obtain
nominal voltage.
Yes
No
Main logic PCB
(E63-700*) failure
Yes
Yes
Are the all data of input
confirmation menu set to
“ALL”?
MENU> MAINTENANCE>
I/O > INPUT
Set
“ALL” or correct
data input port name.
No
Yes
Main logic PCB
(E63-700*) failure.
*Subject to version change
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......