3.1.3.3 Scanner unit 25kW (RB809)
Make sure the radar system is turned off.
4) Disconnect connector P2 from J2
[E62-110X].
3) Pull out the TR unit.
TR unit
2) Disconnect connector P3 from J3
[E61-120X].
Remove the two fixing bolts.
(Tool: Wrench 13mm)
P3 <- J3
PCB: E61-120X
Bolt
Bolt
1) Remove the back cover by loosening four fixing
bolts.
(Tool: Wrench 13mm)
P2 <- J2
PCB: E62-110X