MDC-7000/7900 Series
Chapter 6 Maintenance
0092669002-07
6-11
8) Fasten four screws by non-magnetic
screwdriver.
Screw: PWSM 4x12B (
Quantity 2)
PWSM 4x10B (Quantity 2)
Washer: 2W4B (
Quantity 2)
Caution:
Use a non-magnetic screwdriver, because
the contact of the metal tool with the
magnetron will cause deterioration of its
performance.
Use a non-magnetic screwdriver
Screw: PWSM 4x10B
Washer: 2W4B
Screw: PWSM 4x12B
9) Solder the yellow wire and green
wire to the pulse transformer
terminals.
Attach the shield cover to the
PCB [E62-110X].
Solder two wires.
Yellow wire
Green wire
Terminal-6
Terminal-8