4.2.7 Setting of latitude and longitude (POSITION)
When AIS and MAP functions are used, it is necessary to input position data from GPS or navigation
devices.
(1) [MAINTENANCE] => [I/O] => [POSITION] => [POSITION] => Select [AUTO], [GNS], [GGA], [GLL],
[RMC], [RMA], or [MAN], and press ENT key.
Set value: AUTO, GNS, GGA, GLL, RMC, RMA, MAN,
MAN: Manual input function as an emergency measure when positioning device such as GPS is faulty.
4.2.7.1 How to input the POSITION value by manual
(1) [MAINTENANCE] => [I/O] => [POSITION] => [POSITION] => [MAN], and press ENT key.
(2) [MAINTENANCE] => [I/O] => [POSITION] => [LAT MAN] => [VALUE] will show the current setting
of the input value by highlighting the last digit value by the trackball.
(3) Move the TRACKBALL up or down to set the value. Press ENT key to save the set result.
(4) [MAINTENANCE] => [I/O] => [POSITION] => [LON MAN] => [VALUE] will show the current setting
of the input value by highlighting the last digit value by the trackball.
(5) Move the TRACKBALL up or down to set the value. Press ENT key to save the set result.
Note:
The manual input data is displayed with yellow color.
4.2.7.2 Compensation of POSITION data
When the geodetic system in navigator and that in the map used are different, the position may become
different even with the same values of latitude and longitude. In this case, input of [OFFSET] allows
these positions to be matched.
[MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [OFFSET] => [DTM] or [MAN], and press
ENT key.
Set values: DTM and MAN
MAN: Setting is done by manual input of values.
AIS cannot be displayed because radar DATUM differs from DATUM of AIS when you used position
offset.
4.2.7.3 How to input the compensation of position data by manual
(1) [MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [OFFSET] => [MAN], and press ENT
key.
(2) [MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [LAT MAN] => [VALUE] will show the
current setting of the input value by highlighting the last digit value by the trackball.
(3) Move the TRACKBALL up or down to set the value. Press ENT key to save the set result.
Setting value: 1.000S to 1.000N
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......