Chapter 5 Troubleshooting and on board repair
MDC-7000/7900 Series
5-22
0092669002-07
TP_PLUSE_W shape
Yes
No
RF module (RFM-100) failure
Control PCB failure
No manual tuning
Is J1-1 pin +24V of RF
module normal?
Failure of wiring in Antenna
unit, or failure of Display unit
power
Is RF module Pin J1-8
voltage varied within 6 to
9 volt by manual
adjustment?
No
Yes
No transmission
Pulse length A(us) B(ms)
L2
1.4
1.5 to 1.6
Magnetron failure
Failure of wiring in
Antenna unit, or failure of
Display unit power
Modulator PCB failure
Check connecting cable
between Display unit and
Antenna unit.
Modulator PCB failure
Modulator PCB failure
Yes
No
Is 6.3 V applied to a
magnetron heater?
No
Yes
Is transmitter TXHV fuse
blown?
No
Yes
Is +250 V (J1-1) on
modulator PCB normal?
No
Yes
Is trigger signal
(TP_PLUSE_W) on
modulator PCB normal?
No
Yes
Is there any abnormal
sound from pulse
transformer?
A
B
5 V
0 V
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......