MDC-5200/5500 Series
Chapter 5 Troubleshooting and on board repair
0092655002-03
5-29
5.4 On board repair
5.4.1 Replacement of fuse
The location of the fuses is on the back panel of Display unit.
Fuse type and rating
Application
Type, dimension (mm)
Fuse characteristic
Rating
Main power
Tubular (φ6.4 x 30)
Normal blow
15 A
Modulator high voltage
Tubular (φ5.2 x 20)
Normal blow
0.8 A
Antenna drive motor
Tubular (φ5.2 x 20)
Normal blow
5A
Fuse location
Figure 5.2 Fuse locations on display unit back panel
Modulator
High voltage
Antenna
Drive motor
Main power
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......