4.2.7 Setting of latitude and longitude (POSITION)
When AIS and MAP functions are used, it is necessary to input position data from GPS or navigation
davices.
(1) [MAINTENANCE] => [I/O] => [POSITION] => [POSITION] => Select [AUTO], [GNS], [GGA], [GLL],
[RMC], [RMA], or [MAN], and press ENT key.
Set value: AUTO, GNS, GGA, GLL, RMC, RMA, MAN,
MAN: Manual input function as an emergency measure when positioning device such as GPS is faulty.
4.2.7.1 How to input the POSITION value by manual
(1) [MAINTENANCE] => [I/O] => [POSITION] => [POSITION] => [MAN], and press ENT key.
(2) [MAINTENANCE] => [I/O] => [POSITION] => [LAT MAN] => [VALUE] will show the current setting
of the input value by highlighting the last digit value by the trackball/joystick.
(3) Move the trackball/joystick up or down to set the value. Press ENT key to save the set result.
(4) [MAINTENANCE] => [I/O] => [POSITION] => [LON MAN] => [VALUE] will show the current setting
of the input value by highlighting the last digit value by the trackball/joystick.
(5) Move the trackball/joystick up or down to set the value. Press ENT key to save the set result.
Note:
The manual input data is displayed with yellow color.
4.2.7.2 Compensation of POSITION data
When the geodetic system in navigator and that in the map used are different, the position may become
different even with the same values of latitude and longitude. In this case, input of [OFFSET] allows
these positions to be matched.
[MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [OFFSET] => [DTM] or [MAN], and press
ENT key.
Set values: DTM and MAN
MAN: Setting is done by manual input of values.
AIS cannot be displayed because radar DATUM differs from DATUM of AIS when you used position
offset.
4.2.7.3 How to input the compensation of position data by manual
(1) [MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [OFFSET] => [MAN], and press ENT
key.
(2) [MAINTENANCE] => [I/O] => [POSITION] => [OFFSET] => [LAT MAN] => [VALUE] will show the
current setting of the input value by highlighting the last digit value by the trackball/joystick.
(3) Move the trackball/joystick up or down to set the value. Press ENT key to save the set result.
Setting value: 1.000S to 1.000N
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......