Chapter 5 Troubleshooting and on board repair
MDC-5200/5500 Series
5-18
0092655002-03
Is X2 connector of
SCAN PCB
connecting?
1
Yes
Change motor brushes with new set.
No
Yes
Yes
No
Yes
No
Is motor brush length within
nominal value (at least 6 mm)?
Motor failure
Error message “Azimuth
abnormal.” is displayed.
Is motor rotating?
Go to
“Antenna
does not rotate”.
(page 5-13)
Error
message “Head line
signa
l abnormal.” is
displayed.
Is motor rotating?
Failure of motor power or wiring in
Antenna unit, or failure of Display
unit power
Yes
Is motor drive power +24V at X12-1
pin normal?
No
No
Go to Antenna does not
rotate.
(page 5-13)
Failure of Heading SW
Connect properly.
SCAN PCB failure