MDC-5200/5500 Series
Preface
0092655002-03
1
Preface
[Precaution for safety issues]
Precaution for operation
• Caution about rotating antenna:
The radar antenna may start rotating without notice. Please keep away from the antenna for your
safety.
• Caution about health risks caused by radio wave:
Powerful electromagnetic waves are emitted from the antenna during operation. These waves can
cause ill effects on human bodies when exposed to continuous radiation.
International criteria
Though the international regulation states that the electromagnetic waves with a high-frequency
power density of not more than 100 W/m
2
do not have an ill effect on human bodies, medical
devices such as a pace makers are sensitive to electromagnetic waves with minute electric power
and their operation may become unstable. In any event, any person with such a device must keep
away from electromagnetic sources.
Specified power density and distance from antennas (according to the
provision as specified in IEC 60945)
Transmission power / antenna
length
100 W/m
2
50W/m
2
10 W/m
2
4 kW / 3 feet antenna
0.9 m
1.3 m
m
2.8 m
M
4 kW / 4 feet antenna
1.0 m
1.4 m
3.1 m
4 kW / 6 feet antenna
1.2 m
1.7 m
3.7 m
6 kW / 4 feet antenna
1.5 m
2.1 m
4.5 m
6 kW / 6 feet antenna
1.7 m
2.4 m
5.4 m
12 kW / 4 feet antenna
2.1 m
2.9 m
6.4 m
12 kW / 6 feet antenna
2.4 m
3.4 m
7.6 m
12 kW / 9 feet antenna
2.9 m
4.1 m
9.0 m
25 kW / 4 feet antenna
2.9 m
4.1 m
9.2 m
25 kW / 6 feet antenna
3.5 m
4.9 m
10.9 m
25 kW / 9 feet antenna
4.1 m
5.8 m
13.0 m
• Caution about dangerous internal high voltage in the device:
High voltage that may cause risk of life is present in the Antenna unit and the Display unit of this radar.
This high voltage can remain in the circuit after the switch has been turned off. The high-voltage circuit
has a protective cover with a label “Caution against high voltage” so that no one will accidentally touch
it. Please ensure for your safety that the power switch is turned off and residual voltage in the capacitor
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......