Chapter 5 Troubleshooting and on board repair
MDC-5200/5500 Series
5-30
0092655002-03
5.4.2 Replacement of Internal Battery
The Display unit has a battery built-in. Battery is used only for an internal clock.
When the battery runs low, the internal clock of the radar will not always work properly.
Please exchange the internal battery.
Exchange method of the internal battery is explained as below.
1. Remove 10 fixed screws on the back of the display unit.
2. Remove the front panel from the main chassis by disconnecting the internal cable.
3. Exchange the internal battery on
the Logic PCB
(E63-700*).
Battery type
name: CR2032
Front
panel
Main chassis
*Subject to version change