Chapter 5 Troubleshooting and on board repair
MDC-5200/5500 Series
5-4
0092655002-03
B C
12000 10
35 Change to ground
stabilization
Speed: VBW or VHW is not input.
Change to ground stabilization. Check
VBW or VHW sentence.
B C
12000 11
36 Change SOG input to
EPFS
Change SOG input source from SDME: J6
(VBW) to EPFS: J5 (VTG).
B C
16000
1
47 Inter-switch not
connected.
NAV: J3 ports between master and slave
are not connected.
B C
16000
2
59 AIS alarm signal.
Alarm for abnormality is input in AIS alarm
terminal of AIS port or the terminals are
open.
B C
16000
3
66 No WGS84 DATUM.
Input geodetic system is not WGS84.
A A
17000
1
41 Antenna not connected.
Connector of Antenna may not be
connected to Antenna, or Scanner unit
may be faulty.
A A
17000
2
42 Antenna magnetron
current abnormal.
Magnetron may be at the end of life or
transmission high voltage fuse blown.
A A
17000
3
43 Antenna magnetron
heater abnormal.
Something is wrong with magnetron or
Scanner unit.
A A
17000
4
44 Antenna magnetron high
voltage abnormal.
High voltage fuse for transmission blown.
A A
17000
5
45 Antenna high voltage
abnormal.
High voltage fuse for transmission blown.
A A
17000
6
46 Motor voltage abnormal.
Motor voltage fuse blown.
A A
17000
7
48 Azimuth abnormal.
BP signal from Scanner unit is not
received.
May be fault in angle detecting sensor in
Scanner unit or poor connection at
connector.
A A
17000
8
49 Head line signal abnormal. SHF signal from Scanner unit is not
received.
May be fault in SHF sensor in Scanner unit
or rotation of antenna may be stopped.
A A
17000
9
50 Trigger abnormal.
Trigger from Scanner unit is not received.
A A
17000 10
51 Radar video abnormal.
IF video from Scanner unit is not received.
A A
18000
1
13 Panel not connected.
(MDC-5500 series only)
No communication between operating
panel is available. Connector (J9) is
disconnected.
B W
18001
1
37 Flash memory erase &
write error.
Flash memory erase and write error.
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......