MDC-5200/5500 Series
Chapter 6 Maintenance
0092655002-03
6-5
3) Remove four screws by non-magnetic screwdriver.
Caution:
Use a non-magnetic screwdriver,
because the contact of the metal tool with the
magnetron will cause deterioration of its
performance.
Non-magnetic
screwdriver
4) Following above picture cut the excess wires from magnetron.
New magnetron
MSF1421BY
130mm
Yellow wire
140mm
10mm
10mm
: Remove the insulation sheath
Green wire