background image

 

 

 

 

Manual 

Copyright ©Sigicom AB 2016                                   ML-3250-0EnA 
 

    
 

INFRA X20SR 

Speed Radar 

 

 

 

Art no. 080-03250-0 
 

Manual 

ver. A   

                    Valid for firmware version 1.1.0 

 
 

  

 

 

Read instructions on safety and electrical equipment waste recycling before 
operating this product. 

Summary of Contents for INFRA X20SR

Page 1: ...Sigicom AB 2016 ML 3250 0EnA INFRA X20SR Speed Radar Art no 080 03250 0 Manual ver A Valid for firmware version 1 1 0 Read instructions on safety and electrical equipment waste recycling before operat...

Page 2: ...equipment Operating conditions This equipment is designed for outdoor use and wet locations but is not immersible It is designed according to IEC60529 IPX7 Temperature range for full functionality is...

Page 3: ...2009 category 9 monitoring and control instruments Scrapped equipment should be sent back to the manufacturer of the equipment Sigicom for proper handling according to the WEEE directive Sigicom s pa...

Page 4: ...2 Display devices 7 4 Configuration and operation 8 4 1 Mounting 8 4 2 Lobe 10 4 3 Range 11 4 4 Angle error correction 11 4 5 Mounting check 12 4 6 Parameters 13 4 7 Quick start 14 4 8 Error indicati...

Page 5: ...ures An overview of the measured quantities Gives also introduction to display devices within INFRA Chapter 4 Configuration and operation Mounting description and a detailed description of X20SR s sta...

Page 6: ...in protective packaging Please verify the package content with the following list INFRA X20SR Speed Radar Unit Please report any damage or shortage immediately to Sigicom Record the instrument s seria...

Page 7: ...rgest reflected signal level to represent the interval Movements toward the unit are presented as positive values and movements away from the unit are presented as negative values All quantities that...

Page 8: ...hour km h Calculation which is over the selected interval time is made inside the X20SR 3 2 Display devices Your X20SR Speed Radar shall be connected to the INFRA Field Monitoring System Preferably u...

Page 9: ...ably use a stable pole combined with proper mounting details as shown below for mounting of the unit The unit has a RAM Mount 1 5 RAM Ball Base attached to its back side RAM Mount products is widely a...

Page 10: ...mmended to position the radar 5 10 meters from the rail and direct the radar sideways so that it aims to the center of the rail 40 70 meters away The radar should be approximately 1 5 meter above the...

Page 11: ...to the object of measurement The lobe has different width depending on its alignment It is recommended to mount the radar so that the lobe is wide in the horizontal plane for measurements on fast vehi...

Page 12: ...field tests 4 4 Angle error correction Depending on how the radar is mounted there might be need for certain correction on the measured speed due to the angle in which the radar measures If following...

Page 13: ...simply fixed by directing the radar further down the rail increase L But then the total range of the radar might become an issue instead In such a situation a rule of thumbs could be to assure that 7...

Page 14: ...m h Top speed during interval measured in kilometers per hour km h the resolution is 2 km h 4 6 2 Interval time The interval time is how often the measured speed value is registered The minimum interv...

Page 15: ...available INFRA Sensor Cables 2 Start the Datalogger and wait for initialization process to be finished 3 Under the menu Nodes you ll find your SR unit as SR X20SR serial no where SR is the customer...

Page 16: ...ndication If the speed radar malfunctions the Datalogger displays Node lost after about two minutes 4 9 LED indications An upper middle red flash is shown when each interval is saved A lower right gre...

Page 17: ...e to Sigicom for calibration and adjustment See contact information below Recommended calibration interval is 12 months If sent to repair please carefully write down the description of the problem It...

Page 18: ...s Bus cables in selected lengths Bus cables in special lengths on special order please contact Sigicom Self vulcanizing tape art no 080 01892 0 Window feed through cable art no 080 01472 0 T port art...

Page 19: ...18 Copyright Sigicom AB 2016 7 Contact and support Address Sigicom AB Alfred Nobels All 214 SE 146 48 Tullinge SWEDEN Phone 46 8 44 99 770 Internet www sigicom com E mail support sigicom se...

Page 20: ...ght Sigicom AB 2016 19 Appendix A A 1 Power consumption During measuring X20SR Speed Radar consumes approximately 320mW A 2 Mechanical data Housing protection class IPx7 Weight with ball base 890 g 2...