4-12
A-61593 September 2007
NSO29
Recovery of terminated
run (0) completed
Informational
. Termination of the previous run has been continued
successfully by the recovery.
NSO30
UserField (2): access
error.
UserDIIWrapper.exe
unloaded
The wrapper process for all user fields has been terminated.
Solution
: Check for ‘UserDLLWrapper.exe’ in the Task Manager. If it
does not exist, an unstable user function has terminated it.
NSO31
UserField (2): contains
illegal characters
Illegal control characters contained in data returned from a user function.
Solution
: Check the User function.
NSO40
Compare:Mandatory
field (2) not present in
logic
A mandatory field for the compare module / configuration is not defined.
Solution
: Check the logic.
NSO41
Compare:Mandatory
field (2) not present in
RCT file (2)
A mandatory field for the compare module / configuration is missed in the
rct file.
Solution
: Check for completeness of the rct file or deactivate field check
(see Compare options: Run Open validation on
Compare
fields).
NSO42
Compare:Read/Access
error RCT file (2)
The rct file cannot be read.
Solution
: Check to be sure the rct file exists and that you have
permission to read/access the file. Verify that the rct file has an xml file
structure.
NSO43
Compare:Field(s) not
present in RCT file: (2)
The field is not present in any record of the rct file.
Solution
: Check the usage of the
Compare
field or deactivate field
check (see Compare options: Run Open validation on
Compare
fields).
NSO44
Compare:Field(s)
inconsistent in RCT
file: (2)
The field content does not match with the Run Definition (e.g., there is no
doctype list supplied if multiple parsers are defined).
Solution
: Check the usage of the
Compare
field or deactivate field
check (see Compare options: Run Open validation on
Compare
fields).
OCX Interface errors
OCX001
Machine/Module was
switched off
Solution
: Turn the scanner on and restart the PC.
OCX002
Parity error
Machine interface problem.
Solution
: Check the connection to the scanner to be sure it is securely in
place.
OCX003
Command in this
condition not allowed
Tuning problem.
Solution
: Jam handling.
OCX004
Command with
unknown ID
Internal error or unsupported function of the scanner.
Solution
: Adapt definitions to the scanner.
OCX005
Command with
unknown parameter
Wrong parameter in the Run Definition.
Solution
: Compare the scanner specific parameters with the current
Run Definition.
OCX006
Machine is offline
The scanner has been turned off.
Solution
: Turn on the scanner.
OCX007
Machine not ready
There is a problem with a specific module.
Solution
: Jam handling. If this error happens again, restart the operating
system software.
OCX008
Action not on selected
module
Internal error.
Solution
: Reset the scanner.
OCX009
Command came too
late
Control computer overloaded.
Solution
: Jam handling. If this error happens again, restart the operating