FP 25 E
Issue: 06/2011
16
2 .3 .6 Connecting the Water Cooling
The film gate, the intermittent motor and its amplifier are water-cooled.
ATTENTION
U
A water flow of 2 to 3 l/min is needed to get a water temperature of 18° C ± 2° C
(64° F ± 10° F).
U
The water temperature should not be less than 16° C, because of condensed water
in the projector.
U
If possible the heat exchanger must not have more than 10 m distance to projector
and refrigerating set must not have more than 15 m distance to heat exchanger.
If environment temperature is high and wires are long, the hose is to be isolated
because of condensation water.
• Connect the inlet and outlet tubes of
the water cooling system to the con-
necting pieces in the projector.
X
NOTE
You will find the description of the
water cooling unit in the corresponding
operating manual.
2 .4
Connecting the Projector
ATTENTION
Connecting the projector should only be carried out by electricians or service personnel!
$
The projector is connected to mains current via the terminal strip in the spool tower or
the spool rack.
Summary of Contents for FP 25 E PREMIERE
Page 2: ......
Page 22: ...FP 25 E Issue 06 2011 10 ...
Page 56: ...FP 25 E Issue 06 2011 44 ...
Page 64: ...FP 25 E Issue 06 2011 52 ...
Page 104: ...FP 25 E Issue 06 2011 92 Figure 1 1A 1C 1B 1D Figure 2 2A Fig 2A Fig 2B Fig 2C 2D 2B ...