FP 25/30/38/50 E
Safety Instructions
Issue: 06/2011
3
X
NOTE
This symbol indicates where notes, user tips and useful information can be found.
They serve to help use the projector to its fullest.
Always wear
face protection
when changing the xenon lamp.
Always wear
protection gloves
when changing the xenon lamp.
Always wear
protection jacket (Kevlar)
when changing the xenon lamp.
1 .3
Special Hazard Points
1 .3 .1 Electric Power Hazards
DANGER
S
The access to power supply must always be kept closed. Only authorized service
personnel may access this area.
S
Installation according to the local electrical code and regulations an work on the
electrical supply conductors or circuits must only be done by qualified technical
personnel.
S
This projector should be operated from an AC power source. Ensure that the mains
voltage and capacity matches the projector electrical ratings. Do not defeat the pur-
pose of the grounding.
S
Do not allow anything to rest on the power cable and do not locate the projector
where persons will walk on the cable.
S
Do not operate the projector with a damaged cable or if the projector has been
dropped or damaged - until it has been checked for operation by a qualified service
technician.
S
Position the cable so that it will not be tripped over, pulled, or contact hot surfaces.
S
If an extension cable is necessary, a cable with a current rating at least equal to that
of the projector should be used to avoid overheating of the cable.
S
Do not spill liquids of any kind on this projector. If any liquid is coming into the pro-
jector, switch off, disconnect from mains and call service.
S
Do not use an accessory attachment which is not recommended by the manufac-
turer.
S
The rectifier must be exclusively enabled from projector only.
S
The 4060 DC ignition unit is directly supplied via the rectifier. Therefore the lamp
can be ignited by switching on the rectifier itself. Igniting the lamp by switching on
the rectifier at open lamphouse can cause serious injuries and damages to the lam-
phouse and projector.
S
The safety devices in the lamphouse (door switches and air flow switch) must not be
deactivated. Safe service work on open lamphouse is possible with functional safety
devices only, because rectifier and mains power will be switched off.
Summary of Contents for FP 25 E PREMIERE
Page 2: ......
Page 22: ...FP 25 E Issue 06 2011 10 ...
Page 56: ...FP 25 E Issue 06 2011 44 ...
Page 64: ...FP 25 E Issue 06 2011 52 ...
Page 104: ...FP 25 E Issue 06 2011 92 Figure 1 1A 1C 1B 1D Figure 2 2A Fig 2A Fig 2B Fig 2C 2D 2B ...
Page 110: ...FP 25 E Issue 06 2011 98 10A Figure 11 Figure 11 11A 11B 11C Fig 11A Fig 11C Fig 11B ...