FP 25 E
Issue: 06/2011
41
3 .10 Lamphouse Components
1
2
8
12
9
3
10
4
6
5
7
11
Xenon bulb
Anode (+) cable
Anode connecting bolt
Bulb support (up to 7,000 W only)
Mirror
Mirror holders and protection shield
Stabilizing magnet
Ignition base
Cathode (-) cable
Terminal strip
Mirror adjustment screws
Fan
DANGER
S
The xenon lamp can only be ignited, when the lamphouse door is closed. If you
open the door during the operation the door switch will be activated and the xenon
lamp will turn off immediately.
S
You can suffer hurts when broken glass is flying around (xenon bulb has an inner
pressure of 8 to 10 bar in cold condition and about 30 bar in hot condition).
Because of that you have to wear a protective suit, protective gloves and a face/
neck protection during all works with lamphouse open.
Components - Lamphouse
Summary of Contents for FP 25 E PREMIERE
Page 2: ......
Page 22: ...FP 25 E Issue 06 2011 10 ...
Page 56: ...FP 25 E Issue 06 2011 44 ...
Page 64: ...FP 25 E Issue 06 2011 52 ...
Page 104: ...FP 25 E Issue 06 2011 92 Figure 1 1A 1C 1B 1D Figure 2 2A Fig 2A Fig 2B Fig 2C 2D 2B ...
Page 110: ...FP 25 E Issue 06 2011 98 10A Figure 11 Figure 11 11A 11B 11C Fig 11A Fig 11C Fig 11B ...