2 .3 .3 Additional Installation Hints
ATTENTION
U
The 16
2
PE lines have to be high-flexible to derive the high-frequency ignition
voltage.
U
Do not use the wires in the lamphouse cable to connect the additional dowser.
Lay the dowser connection in the lamphouse tube as short as possible.
U
If you install an old building projector remove all not used old cables, wires and lines
under the projector.
U
If possible the heat exchanger must not have more than 10 m distance to the
projector and the refrigerating set must not have more than 15 m distance to the
heat exchanger. If the environment temperature is high and the wires are long, the
hose is to be isolated because of condensation.
U
The cooling water temperature has to be more than 15° C, to avoid a precipitation of
condensed water on the film gate and the front gate.