FP 25 E
Safety Instructions
Issue: 06/2011
9
1 .6 .6 Lamphouse Airflow Switch
As soon as the projector is switched on, the radial blower starts the operation. It is rea-
sonable to cool the xenon bulb directly.
If the air flow is interrupted, the xenon lamp will be switched off by the airflow switch
(arrow).
If the projector and the xenon lamp are switched off, the blower should run after about
ten minutes.
1 .6 .7 Heat Filter
Lamp power more than 2500 W needs a heat filter which has to be mounted in the lam-
phouse or in the projector’s film gate (see figure).
Lamphouses with metallic mirrors and all big lamphouses (4,000 - 7,000 W lamp power)
are equipped with a heat filter (200 x 200 mm).
The small lamphouse (700 - 3500 W lamp power) has no heat filter. But if necessary, a
heat filter (78 x 78 mm) can be inserted in the film gate.