FP 25/50 E / FP 25/50 D / FP 10/50 A
Issue: 06/2011
84
Up to 7000 W xenon bulbs:
• Loosen the bulb support and put it down.
• Put the protective bonded fabric or a strong cloth around the unpacked bulb.
• Loosen the bulb fixing screw with an Allen key through the lamphouse opening.
• Remove the bulb and then the adapter on the bulb socket by loosening the fixing
screw.
• Pack the used xenon bulb.
• Fasten adapter onto the new xenon bulb (arrow) - bulb is packed in protective bonded
fabric.
• Thread the xenon bulb through the central mirror hole and fasten it by tightening the
Allen screw from the lamphouse outside.
Before inserting the 7,000 W bulb, turn the axial adjustment so far as possible in
forward direction to get more space.
• Remove the protective coat and connect the anode cable to the lamphouse socket.
ATTENTION
U
Position the anode cable away from any metal components as far as possible espe-
cially when inserting xenon bulbs with 40 cm anode cable.
U
Do not mechanically stress the anode cable to avoid bulb explosion.
$
The bulb support stays down for adjusting the screen illumination.
• Close the lamphouse door.
Summary of Contents for FP 25 E PREMIERE
Page 2: ......
Page 22: ...FP 25 E Issue 06 2011 10 ...
Page 56: ...FP 25 E Issue 06 2011 44 ...
Page 64: ...FP 25 E Issue 06 2011 52 ...
Page 104: ...FP 25 E Issue 06 2011 92 Figure 1 1A 1C 1B 1D Figure 2 2A Fig 2A Fig 2B Fig 2C 2D 2B ...
Page 110: ...FP 25 E Issue 06 2011 98 10A Figure 11 Figure 11 11A 11B 11C Fig 11A Fig 11C Fig 11B ...