PFX2512 pattern charge/discharge
The data is acquired under the following conditions.
System requirements
Measuring conditions
Pattern current waveform (measured by the current probe)
Setting conditions
Charge/discharge system controller
PFX2512
Power supply
PWR800L
Electronic Load
PLZ1004W
The DUT (battery)
Use a 14 mm
2
cable with a length of 5 m to connect to a 25.9 V, 40
Ah Li-ion battery module.
Current probe
3274 (HIOKI)
Oscilloscope
TDS3032 (Tektronix)
2 values CC pattern charge/discharge
Step 1
CHG: 50 A 500 ms
Step 2
DISCHG: 50 A 500 ms
50 A
(CHG)
-50 A
(DISCH)
0 A