PFX2512
21
Combination for Performing Charge/Discharge Tests
1
Gen
e
ra
l Des
cr
ipt
io
n
Selecting the appropriate DC power supplies and Electronic loads
The range is different between charging and discharging. Select DC power supplies and electronic
loads that meet each condition.
The graph below shows the range of chargeable voltage and current using the following equation.
Use devices whose voltage (constant voltage, cutoff voltage) and current (constant current) do not
exceed the range.
Maximum charge power = Maximum rated power of DC power supply – Loss in cables
1
1
What is loss in cables?
Voltage drops occur as a result of charge currents flowing through DUT cables, connection
cables, PFX2512 current path circuits, and so on. Loss in cables is the power loss during
charging due to this voltage drop. The maximum power that can be used for charging is the
resultant value after subtracting the loss in cables.
If the allowable power of DC power supplies is exceeded during charging, PS / B alarm or the like
occurs, and the test is aborted.
Voltage (V) axis
Constant voltage value (CV Voltage) or cutoff voltage value (Cutoff voltage)
Current (A) axis
Constant current
value (CC Current)
0
10
20
30
0 5 10 15 20 25 30 35 40 45 50
40
50
PWR800L
PWR1600L
PAS40-
**
PAS20-
**
PAS10-
**
60
70
Charge operation range of the DC power supply [PWR-L/ PAS]
Current (A)
Voltage (V)
PFX2512 Operating range
DUT cable: At nominal cross-sectional area 14 mm
2
5 m
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......