18
PFX2512
Performing Stable System Operation
Suggestions for the PC executing
tests
• Turn off the PC’s sleep mode.
• Set Windows Update to manual mode.
• If possible, do not install virus protection
software.
• Do not run other programs.
• Connect a uninterruptible power supply.
Install a UPS. Be sure to
connect the shutdown signal.
Connecting the shutdown
signal allows BPChecker3000
to automatically shut down the
charge/discharge system in a
safe and orderly manner even
when a power outage occurs
or when the system suddenly
stops for some other reason.
Using a notebook PC
for executing tests is
advantageous in that
you do not need to
use a UPS.
Notebook PC
PC for executing tests (Test Executive)
Uninterruptible
power supply
Shutdown signal
After configuration is
complete, do not
connect the system to
the Internet or
corporate LAN during
charge/discharge
tests.
Switching hub
or router
Wi-Fi router
Avoid using
wireless LAN for
connections.
PC for data analysis (Graph Viewer)
It is safer to use
separate AC
power supplies for
the PC and the
charge/discharge
system.
If you need to run tests for a long time,
using separate PCs for testing and data
analysis will reduce the load placed on the
PCs and allow the tests to run smoothly.
Ideal system shutdown when a power
outage or sudden interruption occurs
(executed automatically)
The PFX2512 charge/discharge system
turns off.
Ļ
The PC remains on using the power from
the UPS.
Ļ
BPChecker3000 detects a communication
error. (Io Err)
Ļ
BPChecker3000 process and protects the
test file.
Ļ
A few minutes later, the UPS sends the PC
a shutdown signal.
Ļ
The PC powers off.
Multicore
processor
8 GB memory
recommended
AC power strip for PC and peripherals
(with a grounding terminal)
AC power cable
LAN cable
AC power strip for charge/discharge devices
(with a grounding terminal)
8Slot Unit
SL01-PFX
DC power
supply
PFX2512 Charge/Discharge System
Charge/Discharge System
Controller PFX2512
Electronic
load
Replacement
with a
notebook PC
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......