SENSe Subsystem
6
Keysight U2741A Programmer’s Reference Guide
79
[SENSe:]CURRent:AC:RANGe
Syntax
[SENSe:]CURRent:AC:RANGe <range|MIN|MAX|AUTO>
This command sets the measurement range for AC current measurements.
[SENSe:]CURRent:AC:RANGe?
This command queries the measurement range for AC current measurements.
Parameter
Remarks
– Selecting a fixed range will disable autorange.
– If the input signal is greater than can be measured on the selected range
(manual range), the U2741A gives an overload indication of
+9.9E+37
from
the remote interface.
– The U2741A is set to 1 A, with autorange enabled, after a factory reset (
*RST
command)
Examples
CURR:RANG 1
//Configures the U2741A to measure AC
current at 1 A range
CURR:RANG?
//Queries the range
Typical Response:
+1.00
See Also
Item
Type
Range of values
Default value
range
Numeric
10 mA, 100 mA, 1 A, 2 A
MIN = 10 mA
MAX = 2 A
1 A