General Specifications
U3022BH10
Frequency Range and Maximum Power Levels
The U3022BH10 frequency range is 10 MHz to 26.5 GHz.
It is recommend that you do not operate near damage levels. The power
levels must be 3 dB below maximum level to ensure no damage. See
Table 5
below.
The examples shown assumes a 10 dBm (0.01w) RF signal and 7 volt DC.
Equation 1 DC Wattage (
E
2
/R = DC Wattage)
Equation 2 Maximum Wattage (RF + DC = Maximum Wattage)
Table 5
Maximum Power Level Inputs
Test Set or PNA-X Front
Panel Connections
Power Level
1 Watt Standard
Configuration
1
Power Level
20 Watt
Configuration
Maximum U3022BH10 Multiport Test Set RF Power Levels:
PORT 3-12
+30 dBm 40 Vdc
+43 dBm 40 Vdc
SRC OUT
+30 dBm 0 Vdc
+30 dBm 0 Vdc
CPLR ARM
+30 dbm 7 Vdc
+30 dbm 7 Vdc
CPLR THRU
+30 dBm 40 Vdc
+43 dBm 40 Vdc
RVCR A IN and B IN
+15 dBm 0 Vdc
+15 dBm 0 Vdc
RVCR R1 or R2 IN
+15 dBm 7 Vdc
+15 dBm 7 Vdc
Damage Power Levels to U3022BH10 Access and Test Ports:
1. All jumpers installed are considered standard configuration.
2. Refer to your PNA-X specifications to determine the maximum input power levels for the access and test ports.
3. Add the RF signal to the DC component to determine the maximum wattage.
4. Isolators and attenuators installed. Refer to
Max Level to Port 1 & 2 Test Ports
+30 dBm 40 Vdc
+43 dBm 40 Vdc
7
v
2
⁄ 50Ω= 0.98
w
0.01
w
+ 0.98
w
= 0.99
w
2
2
3
Source Out, Noise Source In/Out
(Option 129)
+30 dBm 0 Vdc