![Kato REDGZM HD514MR-7 Instruction Manual Download Page 144](http://html.mh-extra.com/html/kato/redgzm-hd514mr-7/redgzm-hd514mr-7_instruction-manual_657904144.webp)
- 128 -
7. Monitor
Icon
displayed
Message displayed
Description
Notes
Actions
Applicability
ELECTRIC SYSTEM
ERROR
USE
"
SWING LOCK RELEASE
"
SWITCH
Displayed when an open or short
circuit occurs in an important
circuit.
The message prevents the swing
lock from functioning normally,
so switch the swing lock release
switch to the release position.
The swing lock is released while
the engine is running.
Contact your authorised
KATO dealer.
COMMUNICATION
ERROR
USE BACKUP SWITCH
Displayed when a communication
error occurs between the APC
controller and ECU.
Switch the backup switch to the
backup side. This temporarily
enables digging operations.
Contact your authorised
KATO dealer.
ACCEL. CONTROL
ERROR
USE BACKUP SWITCH
Displayed when an accelerator
control error occurs.
Switch the backup switch to the
backup side. This temporarily
enables digging operations.
ELECTRIC SYSTEM
ERROR
USE BACKUP SWITCH
Displayed when an open or short
circuit occurs in an important
circuit.
Switch the backup switch to the
backup side. This temporarily
enables digging operations.
COMMUNICATION
ERROR
BACKING UP
Displayed if a communication
error occurs and the backup
switch is switched to the backup
position.
ACCEL. CONTROL
ERROR
BACKING UP
Displayed if an accelerator
control error occurs and the
backup switch is switched to
the backup position.
ELECTRIC SYSTEM
ERROR
BACKING UP
Displayed if an open or short
circuit occurs in an important
circuit and the backup switch is
switched to the backup position.
BACKUP SWITCH
"
ON
"
Displayed when the backup
switch is switched to the
backup position.
When functioning properly, if
the backup switch is in the
backup position, switch it back
to the auto position.
FAILED TO STOP ENG.
USE EMERGENCY STOP SWITCH
Displayed if the engine does
not shut off when the starter
switch is turned OFF.
After shutting the engine off,
move the emergency stop switch
back to the normal position.
・
Use the emergency stop
switch to shut the engine
off.
・
Contact your authorised
KATO dealer.
SCR SYSTEM ERROR
OPERATING IN ESCAPE MODE
Displayed if the escape mode is
enabled when a DEF quality
error or SCR system error is
active.
Contact your authorised
KATO dealer.
ADD DEF
OPERATING IN ESCAPE MODE
Displayed if the escape mode is
enabled when the DEF level is
low.
Replenish the DEF.
SCR SYSTEM ERROR
NO OUTPUT. RPM RESTRICTED.
Displayed if a DEF quality
error or SCR system error
occurred.
Severe operating restrictions are
applied.
The maximum engine output is
restricted and engine speed is
set to low idle.
Restrictions can be temporarily
overridden in the escape mode.
If this screen is displayed, an
alarm sound is emitted several
times.
Contact your authorised
KATO dealer.
ADD DEF
NO OUTPUT. RPM RESTRICTED.
Displayed if the DEF level is
too low.
Severe operating restrictions are
applied.
The maximum engine output is
restricted and engine speed is
set to low idle.
Restrictions can be temporarily
overridden in the escape mode.
If this screen is displayed, an
alarm sound is emitted several
times.
Replenish the DEF.
SCR SYSTEM ERROR
RPM. OUTPUT RESTRICTED
Displayed if a DEF quality
error or SCR system error
occurred.
Severe operating restrictions are
applied.
The maximum engine output
and engine speed are restricted.
Restrictions can be temporarily
overridden in the escape mode.
If this screen is displayed, an
alarm sound is emitted several
times.
Contact your authorised
KATO dealer.
Summary of Contents for REDGZM HD514MR-7
Page 2: ...218621 背厚 13 mm 中 ...
Page 9: ... 7 8 Specifications 8 2 General data 01E0 0023 0E ...
Page 12: ... 10 MEMO ...
Page 56: ... 40 2 Part names and terms 2 2 2 Inside the cab 01E0 0050 1E ...
Page 57: ... 41 Part names and terms 2 Part names and terms ...
Page 58: ... 42 2 Part names and terms 2 2 3 Outside the cab 01E0 0051 1E ...
Page 148: ... 132 8 Lifting a load 2 HD514MR LC 7 ...
Page 183: ... 166 2 Inspection and servicing table 1 Part names for inspection and servicing ...
Page 184: ... 167 Inspection and servicing table 2 Inspection and servicing table ...
Page 185: ... 168 2 Inspection and servicing table ...
Page 200: ... 183 3 Lubrication Lubrication 3 5 Oiling chart 01E0 0293 0E ...
Page 261: ... 244 244 MEMO ...
Page 290: ... 272 MEMO ...
Page 315: ... 296 296 5 Electrical circuit diagram 5 Electrical circuit diagram 01EE 0609 0E ...
Page 316: ... 297 297 5 Electrical circuit diagram Electrical circuit diagram ...
Page 317: ... 298 298 MEMO ...
Page 325: ...899 92186210 ...