Precondition The negative cable to the battery is disconnected.
1. Twist and remove the expansion tank filler cap.
2. Mix a quantity of coolant according to the table and replenish to the mark.
Replenish the coolant just below the
maximum mark
A
.
3. Screw on the filler cap.
4. Reconnect the negative battery terminal.
5. Close the door.
6. Start the engine and allow to IDLE for about 1 minute.
7. Stop the engine.
8. Open the left-hand door.
9. Check the coolant level.
If the coolant level in the expansion tank has decreased: Replenish the coolant.
10. Visually inspect for leaks.
11. Close the door.
If the coolant has been changed, check the level of the new coolant frequently at first as it
can decrease due to the escape of air locks in the cooling circuit.
10.3.1.5 Draining the coolant
The complete volume of coolant contained in the circuit can be drained from the radiator. The wa‐
ter cooler is drained by a separate drain plug (accessible from underneath through the access hole
in the floor pan).
Precondition The machine has cooled down.
The negative cable to the battery is disconnected.