4. Turn the« starter switch» to "ON".
The
charging indicating light must light.
8.2.2 Engine pre-heating
The pre-heating period should be between 5 and a maximum of 10 seconds depending on ambient
temperature. Low ambient temperatures require a longer pre-heating period.
The electric fuel pump starts automatically during pre-heating. This vents the fuel line before
each start.
1.
NOTICE!
Destruction of the glow plug!
Excessive pre-heating can cause severe damage to the glow plug.
➤ Never allow the glow plugs to operate for longer than 10 seconds.
2. Turn the «starter switch» to the “Pre-heat” position and hold for 8 to 10 seconds.
The engine's glow plugs are energised and the engine pre-heated.
8.2.3 Starting the machine
1.
NOTICE!
Destruction of the starter!
Improper operation could destroy the starter.
➤ As long as the engine is running, do not actuate the starter switch.
➤ Do not turn and hold the starter switch for longer than 30 seconds.
➤ Wait for a few minutes after each attempt to start the engine.
➤ The starter switch must be returned to the neutral position before each start attempt (re‐
start protection).
2. Turn the «starter switch »to "START" and release it as soon as the engine starts.
The
charging indicator lamp extinguishes as soon as the engine is running.
8.2.3.1 Option lc
Note the indicator for the diesel particulate filter
Upon activating the «starter switch», the indicator light
Alarm, diesel particle filter will light up briefly
and goes out if there is no fault. The machine can be operated normally. The diesel particulate filter
traps any soot emitted from the engine. When the filter module has reached capacity, the control
unit switches automatically to regeneration.
➤ Note the indication
alarm, diesel particle filter.
Indicating lamp dark: diesel particulate filter works normal.
Indicating lamp flashes or is lit: take measures as described in chapter 9.4 “Faults in the diesel
particulate filter”.
The control unit records the alarm message so it can be proven if the machine continues to
be operated with an illuminated alarm indication. The manufacturer accepts no liability from
consequential damage.
8
Operation
8.2
Starting and stopping
No.: 9_5898 26 E
Operator manual Portable compressor
M 64
71