10.7 Maintenance of Optional Items
➤ Perform maintenance tasks according to the schedule in chapter 10.2.3.2.
10.7.1 Option ec
Tool lubricator maintenance
Material Tool oil (special lubricant for road breakers),
Funnel
Cleaning cloths
Precondition The machine is switched off.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
Fig. 64 Tool lubricator maintenance
1
Filler plug with dipstick and integrated riser
tube
A
Minimum and recommended oil level
2
Tool lubricator upper part with oil filling
port
3
Oil tank
4
O-ring
5
Tool oil
➤ Open the right-hand access door.
Checking the tool lubricator oil level
Check the oil level daily.
A dip stick is attached to the underside of the oil filler plug with which to measure the oil level.
The oil level should be in the upper third of the dipstick.
1. Slowly unscrew and withdraw the oil filler plug.
10 Maintenance
10.7 Maintenance of Optional Items
140
Operator manual Portable compressor
M 64
No.: 9_5898 26 E