8.2.4 Allow the machine to run up to operating temperature
To avoid unnecessary wear, the engine should be run in IDLE until the airend discharge tempera‐
ture r30 °C. The airend discharge temperature is shown at the temperature gauge switch
on the instrument panel.
Fig. 27 Label referring to the warm-up period when ambient temperatures are below -10 °C
➤ Allow the machine to warm up in IDLE (low speed).
8.2.5 Switching to LOAD
Precondition The airend discharge temperature must be at least +30 ℃
1. WARNING!
Compressed air can cause serious injuries.
➤ Never direct compressed air at persons or animals.
➤ Make sure that no one is working on the machine.
➤ Ensure that all panels are in place.
➤ Ensure that all machine doors are closed.
2. Press the «Load On »button.
Result The integrated
LOAD indicator lights and the engine accelerates to maximum speed.
8.2.6 Regulating the shut-off valve
To prevent users' devices from venting when the compressor shuts down and automatically vents,
a shut-off valve is installed in the control air line between oil separator tank and air distributor.